tubra®-eTherm S

Power to heat

The tubra®-eTherm S detects surplus electricity from PV systems, determines the available power and passes it on to an electric heater. In this way, excess electricity is converted directly into thermal energy and stored. Power electronics for stepless control of 3 kW electric heating elements for buffer and drinking water tanks.

  • increasing the self-consumption of the PV system
  • priority for household electricity
  • applicable on all potable water and buffer storage tanks with 6/4 socket to accommodate an electric heating rod
  • energy storage in hot water tanks with significantly higher storage capacities than in batteries
  • optimal for retrofitting to existing storage tanks
  • fast power modulation 0 – 3000 W
  • exact, fast measurement of the excess current
Scheme eTherm S System House
Power extension eTherm

optional functions:

  • 0 – 10 V Control
  • inverter power limitation
  • reheating
  • smart remote access
Typtubra®-eTherm Ptubra®-eTherm C 3 / 9tubra®-eTherm S
AusführungHeizungswasserHeizungswasserTrink- oder Heizungswasser
Modulation VDE konformJaJaJa
nutzbare Speicherkapazität100 %100 %40 - 80 %
Zieltemperaturregelung zur Speicherschichtungelektronischelektronisch-
Max. Betriebsdruck3 bar3 bar-
max. Speicherladetemperatur80 °C80 °C80 °C
Nennleistung0 - 3 kW (13 A)3 kW (0,8 / 0,8 / 1,4 kW)
9 kW (3 x 3 kW)
0 - 3 kW
Abmessung H x B x T605 x 400 x 240 mm605 x 400 x 240 mm226 x 302 x 84 mm
Elektroanschluss1-phasig
PE 230 V AC 50 / 60 Hz
C 3: 1-phasig / C 9: 3-phasig
PE 230 V AC 50 / 60 Hz
1-phasig
PE 230 V AC 50 / 60 Hz
Messung3-phasig*3-phasig
Erforderlicher
Leiterquerschnitt
2,5 mm²2,5 mm²2,5 mm²
Nenninhalt0,2 l0,2 l-
Gewicht13 kg13 kg9 kg
Heizelement0,1-0,8 kW / 0,8 kW / 1,4 kW0,8 / 0,8 / 1,4 kW / 3 x 3 kW3 kW
max. Durchfluss300 l/h900 l/h-
Restförderhöhe100 mbar100 mbar-
Zieltemperatur30 - 70 °C65 °C-
WasseranschlussG1 AG, Rp 3/4 IGRp 3/4 IGG1 1/2
UmwälzpumpePara 15/7 iPWM2Para 15/7 iPWM2-
Leistungsaufnahme3 - 45 W3 - 45 W< 1 W
MaterialienMessing, Edelstahl, KupferMessing, Edelstahl, Kupfer-
SchnittstellenV-BUS, PWM, S0, 0-10V und potentialfreie Kontakte zur Fernsteuerung und als Kommunikations-
schnittstelle vorbereitet.
Pumpenanschluss 230 VAC Heizungsanschluss 1 / 3-phasig 230VAC 50HzKeine
Product portfolio Power to heat

Power to heat stations from tuxhorn store energy in heat accumulators with significantly higher storage capacities than in batteries. They are used exclusively for heating water by means of electric heating element in the flow-through principle.

tubra-eTherm C 3/9

3 kW or 9 kW version

see product

tubra-eTherm P

modulating 0 – 3 kW

see product