Tuxhorn » Product information » Heating » Flat stations
Home station
Thermally controlled apartment transfer stations for efficient 2-pipe networks in multi-family houses for mixed and unmixed heat distribution.
- FSU / FSM >>>
tuxhorn
offers you thermally controlled home stations with a DHW output of 35 to 50 kW and a primary flow rate (DHW max.) of 720 to 1180 l/h.
Find out about our diverse offer.
tubra®-FSU / FSM flat station
The thermally controlled tubra®-FSU / FSM flat station for comfortable, decentralized hygienic potable hot water heating and efficient heating distribution.
For new construction and renovation with extensive standard equipment. Versions for radiator systems, floor heating and combinations.
All versions with copper or stainless steel brazed plate heat exchanger.
- power classes from 35 kW – 50 kW
- Thermal hot water control via
3-way priority control valve - standby temperature 50 °C according to VDI 2072
- hot water comfort levels
- and much more
- Plate heat exchanger, copper brazed (Cu), optionally stainless steel (VE)
- Thermostatic head for 3-way control valve
- Thermostatic 3-way control valve with hot water priority
- water hammer damper
- Thermostatic return temperature limiting valve for hot water preparation
- Thermostatic head for return temperature limitation with copper coil sensor
- Heating zone valve M30 x 1.5 for mixed heating circuit
- electrothermal actuator
- Heating zone valve for mixed heating circuit (injection circuit)
- Thermostatic head with remote sensor for fixed-value control of the flow temperature of the mixed heating circuit (20 – 50°C)
- Return temperature limiting valve for unmixed heating circuit
- Thermostatic head M30 x 1.5 for return temperature limitation
- High temperature outlet for bathroom radiators (2nd heating circuit)
- Floor circuit pump for mixed heating circuit
- Contact thermostat as a safety temperature limiter to prevent excessive flow temperatures in the mixed heating circuit
- Differential pressure regulator 30 kPa
- Fitting piece for heat meter ¾” x 110 mm
18. Strainer with discharge connection for differential pressure regulator and
WMZ-VL sensor M10*1
19. Fitting piece for cold water meter ¾” x 110mm
20. Circulation set incl. pump, safety valve and ball valve
(optional accessory)
21. Mounting connection plate with 7 or 9 ball valves (optional accessory)
18. Strainer with discharge connection for
Differential pressure regulator and
WMZ-VL sensor M10*1
19. Fitting piece for cold water meter ¾” x 110mm
20. Circulation set incl. pump and
safety valve and ball valve
(optional accessory)
21. Mounting connection plate with 7 or
9 ball valves (optional accessories)
A: PWH-C* – DHW hot
Circulation
B: PWC* – DHW cold, apartment
C: PWC* – DHW cold, primary
D: PWH* – DHW hot
E: HV – Heating water flow, primary
F: HR – Heating water return, primary
G: HR – heating water return, mixed
H: HV – heating water flow, mixed
I: HR – heating water return,
unmixed
J: HV – heating water flow,
unmixed
*Abbreviations according to DIN EN 806 Part 1
PWC: Potable Water Cold, drinking water, cold – color coding: green
PWH: Potable Water Hot, drinking water, warm – color coding: red
PWH-C: Potable Water Hot-Circulation, drinking water pipe, warm, circulation – color coding: violet
Product group Home stations

Flat station with circulation
tubra®-FSU / FSM
DHW flow rate 60/10 – 45 °C with 14 to 20 l/min

Flat station without circulation
tubra®-FSU / FSM
DHW flow rate 60/10 – 45 °C with 14 to 20 l/min