eTherm P ISO
    eTherm P ISO
eTherm P
    eTherm P

tubra®-eTherm P

Power to heat

The station for storing surplus electrical energy as heat in the buffer or hot water tank

  • stepless power modulation according to VDI guidelines
    and EMC compliant => CE mark
  • loading the buffer tank for high storage capacities
    through target temperature control
  • a system controller for current measurement, power control and storage charge management
  • independent of PV components, completely pre-assembled
System eTherm P System House
Scheme eTherm P heating power
Power extension eTherm

optional functions:

  • reheat function
  • additional consumers – up to 12 kW stepless modulation
  • inverter power limitation
  • remote control Smart Remote
  • adjustable reserve power for peak shaving of PV peaks
  • combination with heat pumps – Smart Remote ready
  • combination with batteries – maximum PV self-consumption
  • cascading of one eTherm P and one eTherm C possible
System eTherm P Power extension
Power extension eTherm cascade

combination of tubra®-eTherm P and tubra®-eTherm C

  • total thermal power 12 kW
  • stepless modulating
  • recommended for buffer tanks from 1500 liters
  • PV systems up to 30 kWp, incl. sensors and power electronics
  • independent of the inverter or energy management systems
System eTherm cascade
Typtubra®-eTherm Ptubra®-eTherm C 3 / 9tubra®-eTherm S
DesignHeating waterHeating waterDrinking- or Heating
water
VDE-compliant
modulation
YesYesYes
Usable storage
capacity
100%100%40 - 80 %
Target temperature
control for use of
accumulator layering
electronicelectronic-
max. operating
pressure
3 bar3 bar-
max. accumulator
charging temperature
80 °C 80 °C 80 °C
Rated output0 - 3 kW (13 A)3 kW (0,8 / 0,8 / 1,4 kW)
9 kW (3 x 3 kW)
0 - 3 kW
Dimensions H x W x D605 x 400 x 240 mm605 x 400 x 240 mm226 x 302 x 84 mm
Electrical connection1-phase
PE 230 V AC 50 – 60 Hz
C 3: 1-phase / C 9: 3-phase
PE 230 V AC 50 – 60 Hz
1-phase
PE 230 V AC 50 – 60 Hz
Measurement3-phase*3-phase
Required Conductor
cross-section
2,5 mm²2,5 mm²2,5 mm²
Rated capacity0,2 l0,2 l-
Weight13 kg13 kg9 kg
Radiator0,1-0,8 kW / 0,8 kW / 1,4 kW0,8 / 0,8 / 1,4 kW / 3 x 3 kW 3 kW
max. flow rate300 l/h900 l/h-
Residual delivery head100 mbar100 mbar-
Target temperature30 – 70 °C65 °C-
Water connectionG1 AG, Rp 3/4 IGRp 3/4 IGG1 1/2
Circulation pumpPara 15/7 iPWM2 Para 15/7 iPWM2 -
Power consumption3 - 45 W3 - 45 W< 1 W
MaterialsBrass, stainless steel,
copper
Brass, stainless steel,
copper
-
InterfacesV-BUS, PWM, S0, 0-10V
and zero-potential contacts
prepared for remote control
and as a communication
interface.
Pump connection 230 VAC PWM
Heating connection 1 / 3-phase
230 VAC 50Hz, controller V-BUS,
SD card
None
Product portfolio Power to heat

Power to heat stations from tuxhorn store energy in heat accumulators with significantly higher storage capacities than in batteries. They are used exclusively for heating water by means of electric heating element in the flow-through principle.

tubra-eTherm C 3/9

3 kW or 9 kW version

see product

tubra-eTherm S

modulating 0 – 3 kW

see product