Tuxhorn is one of the leading German manufacturers of valves and pump groups for the hydraulic control of solar thermal systems, heating and fresh water systems. Our competence is based on the know-how of more than 100 years, the consistent customer orientation and the focus on the growing requirements of the international markets.
We are the competent partner for original equipment manufacturers, wholesalers, installers and planners in the fields of
heating, hot water, solar energy, system storage and supply fittings.
Our new tubra®-eTherm Flyer!
Our new flyer for end customers is here. eTherm Hydraulic groups – why, wherefore, why? Make full use of your PV system and significantly increase your self-consumption . Here you will find all the basic information about the tubra® eTherm summarized simply and compactly. Have fun reading!
tubra®-eTherm Flyer >>>
Opening hours / dispatch in the month of May 2024
Please note that due to the upcoming public holidays in May, our company will be closed on both 10.05.2024 and 31.05.2024.
We will be back at the usual times from the following Monday.
Opening hours / dispatch during the turn of the year
Please note that our company will be closed from 18.12.2023 – 31.12.2023.
The last shipping day is on 13.12.2023
From 02.01.2024 we will be back for you at the usual times.
News
tuxhorn components for heat pumps
The new reference guide for system technology from tuxhorn in combination with heat pumps.
In the guide you will find important information about various systems with tuxhorn components for heat pumps for installation in detached houses and apartment buildings.
The guide brochure “Feel-good heat tuxhorn components for heat pumps” is available for you to download.
tuxhorn service partner network
tuxhorn has established its own service partner network.
On-site technical service is being expanded with qualified and specialized service partners.
In addition to the well-known service support for the planning and design of our products
Tuxhorn now also offers on-site services for commissioning or complaints.
Trade fair ISH 2023
for heating, hot water, PV heat, heat pump, biomass and solar.
Simple, fast, space-saving installation of all system components directly on the storage tank with matching connection fittings…
Important dates
Trade fair dates
We are represented at the following trade fairs and look forward to your visit
All dates >>>
EM Power Munich
19.06 to 21.06.2024
Energy management,
networked energy solution
Hall: B5
Stand: B5.536
Workshop dates
Our workshops take place regularly at our head office in Bielefeld.
If you do not find any suitable workshops for you, just contact us. We are looking for a solution to provide you with the knowledge you need to get the most out of all our products and your projects. Your workshop team
All dates >>>
Quickly find the right and relevant information about our products.
All instructions >>>
The 5 latest FAQ answers
Find answers to frequently asked questions about our products here at a glance – FAQ >>>
Solar energy (5)
- ÜSTA stratification loading set: layered, optimum accumulator loading via single or double switchover
- heat meter set
An incorrect flow direction during flushing / cleaning can lead to the cone of the gravity brake being pressed too deeply into the seat and not being released again by itself.
The eTherm is always connected to the electrical system as the last consumer before the bidirectional meter. The direction arrows on the measuring clamps must be set so that they point in the direction of the consumers. The correct polarity on the sensor module must be observed.
For the electrical connection, two additional installation contactors are set as additional auxiliary relays. Usually, a 1-phase and a 3-phase installation contactor must be installed here. The first phase of the cartridge heater is thus connected to the 1-phase contactor, the two remaining phases of the cartridge heater are connected to the 3-phase contactor. It is important to correctly assign the phases to the controller! The single-phase contactor must be connected to the controller as consumer 1 and the second contactor with 2 phases as consumer 2. Now 12,000 watts of continuously modulating power are available.
The eTherm P can control up to two additional consumers by means of external auxiliary relays. With the external consumers, stepless power modulation up to 12 kW can be achieved. The cascade of eTherm P and eTherm C offers a particularly effective combination. Here, the entire output is converted into heat in two hydraulic stations and the storage tank can thus be loaded in layers with a constant target temperature.